If you have been in search of Transformer Power products that are listed with the NSN 5950012714819 we have you covered here on Speedy NSN. You have reached the RFQ page for part number 6C60-140A a Abbott Technologies Inc item that is readily available for procurement from our website at any time. Whether you wish to purchase this part or simply want to receive more information for your comparisons, be sure to fill out and complete the form provided on this page with as much detail as you can regarding your needs and restrictions. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will reach out to you to present a customized quote that keeps your part requirements in mind.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure the exact items they are looking for, we list products with as much information as possible. For example, this particular Abbott Technologies Inc part was produced under the CAGE Code 58910, ], a unique identifier assigned to manufacturers who have been approved to supply government entities. Additionally, with the NSN 5950-01-271-4819 this product also belongs to the FSC 5950 Coils and Transformers. If you ever have any questions regarding our offerings or services, be sure to call or email us at your convenience. Get started on the purchasing process today so we can fulfill all your operational needs as your strategic sourcing partner.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-271-4819 Item Description: TRANSFORMER,POWER | 5950 | 012714819 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6C60-140A | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.437 INCHES MINIMUM AND 3.562 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.609 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.641 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.000 INCHES MINIMUM AND 5.313 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 139.2 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | 4920-01-166-2425 INTERCONNECTING |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.32 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
CRMJ | WINDING POWER RATING | 69.6 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.