If you have been in search of Power Supply products that are listed with the NSN 6130013630912 we have you covered here on Speedy NSN. You have reached the RFQ page for part number 500-2 a Ametek Programmable Power Inc item that is readily available for procurement from our website at any time. Whether you wish to purchase this part or simply want to receive more information for your comparisons, be sure to fill out and complete the form provided on this page with as much detail as you can regarding your needs and restrictions. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will reach out to you to present a customized quote that keeps your part requirements in mind.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure the exact items they are looking for, we list products with as much information as possible. For example, this particular Ametek Programmable Power Inc part was produced under the CAGE Code 25965, ], a unique identifier assigned to manufacturers who have been approved to supply government entities. Additionally, with the NSN 6130-01-363-0912 this product also belongs to the FSC 6130 Converters Electrical Non Rotating. If you ever have any questions regarding our offerings or services, be sure to call or email us at your convenience. Get started on the purchasing process today so we can fulfill all your operational needs as your strategic sourcing partner.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-363-0912 Item PartTypeName: POWER SUPPLY | 6130 | 013630912 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
500-2 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 3RD POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.2 AC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.25 AC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.1 AC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 2ND POWER OUTPUT AND 130.0 AC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 3RD POWER OUTPUT AND 260.0 AC VOLTS MAXIMUM 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 1ST POWER OUTPUT AND 32.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 1ST POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 1ST POWER OUTPUT |
CBBL | FEATURES PROVIDED | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
CWGN | OUTPUT PHASE | TWO 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 16.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F110 ACFT/GE100 ENG |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 2ND POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
CWGN | OUTPUT PHASE | TWO 1ST POWER OUTPUT |
CWGN | OUTPUT PHASE | TWO 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote